Optical Line Protection

Optical Line Protection System for Fiber Protection in Dual Fiber, Bi-directional Protection, 1+1 Optical Line Protection, 1:1 Optical Line Protection, Customized Housing.

Add to quote list
Description

Description

Optical Line Protection System for Fiber Protection

OLP(Optical Line Protection) is used in pairs, one at each end of the optical signal to protect network transmission line. It adopts advanced optical automatic switching modules and is an optical device used for primary and backup optical path switching in fiber optic communication. It can automatically identify the signal status of the primary and backup system optical paths and perform instantaneous switching of the optical path. In case the current optical power of optical fiber is less than pre-set switching threshold value, then alarm is on and it would switch to standby optical fiber automatically to protect optical transmission system line.

Arkoptics provides 2 types of line protection: 1:1 line protection and 1+1 line protection. Wavelengths and connectors can be customized to meet special control and applications. The device is in compact size, available with standard 1U rack mount and Pluggable Module. It is widely used in primary and backup protection of various trunk lines and in networks requiring various optical path switching.

  1. Optical line protection for both single-mode and multimode fiber.
  2. Dual fiber bidirectional and single-fiber bidirectional protection modes available.
  3. Supports 1+1 (dual-transmitter dual-receiver) and 1:1 (transmitter selection receiver selection) protection modes.
  4. Wide optical power monitoring range: -50dBm to +25dBm.
  5. Short optical path protection switching time: <20ms.
  6. Supports local and remote control.
  7. Supports SNMP-based unified network management platform. Include CLI (telnet and console), Web, and NetView (graphical interface).

Specifications

Optical Line Protection
Wavelength Range1310±50nm and 1550±50nm
Detection of Optical Power RangeTx:+2dBm~-50dBm
Rx: +10dBm~-50dBm
Insertion Loss1+1 Protection
Transmitter End ≤4.0dB
Receiver End ≤1.5dB
1:1 Protection ≤1.5dB
Optical Power Measurement Accuracy≤0.5dB(+20dBm~-50dBm)
≤1.0dB(-40dBm~-50dBm)
Optical Power Resolution≤0.01dB
Wavelength Dependent Loss≤0.25dB
Polarization Dependent Loss≤0.1dB
Switching Time≤20ms
Return Loss≤45dB
Crosstalk≤55dB
Network ManagementNetView, Web
Operating Temperature-10°C to +50°C
Storage Temperature-40°C to +85°C
Relative Humidity5% ~ 95%
Power Consumption<5W
Dimension156(W)×20(H) ×225(D) mm
Safety and EMC ComplianceFCC, UL, CE, TUV, CSA standards